Inspections & Testing
American
Quality Roofing performs detailed, professional visual
inspections with state-of-the-art moisture detection devices
and gives thorough explanations with digital pictures.
We promise this, hand delivered, in 24-48 hours. We also
promises reasonable charges on inspections - $125 and up,
based on roof size, condition, detail work and time required.
The inspection fee is deductible from cost of requested
repairs and reroofing.
AFFILLIATE
QUALIFICATIONS (Engineer Testing)
Miami
Dade County Building Code Compliance.
Certified Materials Testing Labratory.
Florida Registered Professional Engineer, R.N. Sailappan, P.E.
TAS 105
- Fastner Withdrawl Resistance Testing
TAS 106 - Uplift Resistance Testing Tile Roof
TAS 109 - Polyurethane Foam Roofing (pending certification).
TAS 124 - Existing and New Roof Wind Uplift Resistance Testing.
TAS 126 - Roof Moisture Survey - Nuclear/Infrared (pending certification)
 |
 |
(Click images to enlarge) |
CERTIFICATIONS
M/WBE
Certification, Dade County, Florida.
A.H.E.R.A. Building Inspector.
Roof Consultants Institute, Roof Consulting.
Troxler Laboratories, Nuclear Testing Equipment Safety.
Anyone
who wants an engineer test should get Florida Roof testing
information as Affiliate.
INSPECTION
PROCEDURES
The starting
point of the Inspection should be the interior of the building.
The interior walls and ceilings should be checked for signs
of water arid staining. After inspecting the interior a
thorough inspection of the exterior walls should be made
along with the roof system.
(Click
to enlarge)
The
following roof components should be inspected:
Flashing: These
are the protection for the membrane termination and often
provide a waterproof cover at the membrane termination.
These include Counter- flashing, expansion joint covers,
copings and flashing at walls and curbs. A variety of problems
may occur at these vulnerable locations.
Penetrations: These
are pipes, drains, vents, stacks and other items that penetrate
the roof membrane. These MUST be flashed properly to assure
a watertight roof system.
Field
Membrane -
What to look for:
· Open
seams excessive blisters, wrinkles, ridges or areas of
non-adhered membrane.
· Worn spots holes or deteriorated areas of the membrane.
· Deteriorated, areas of surface coating on the membrane.
· Adequate, drainage and ponding problems of the membrane.
· Areas around rooftop equipment that may have been degraded by leaks or spills
or punctured by dropped equipment parts.
Leak
Maintenance Procedure:
1.
Protect the interior.
2. Remove excess water from the roof. Check roof drains and scupper
boxes to be certain that they are functional. Excessive ponding on
the roof may cause roof system damage, structural damage or even roof
collapse.
3. Locate the source of the leak by locating the paint an the roof
above the leak in the building's interior.
4. Perform necessary repairs. Once the source of a leak is located,
the materials and procedure used to make the roof watertight will be
determined by the roofing professional.
|